Code Panel, Venous Blood

General Information

Interpretation

Method

HMC:
VO2FR: Photodiode array

VMHB: Photodiode array

WVLAC: Lactate Oxidase

UWMC-NW:

Ion Selective Electrode (ISE)

Reference Range
See individual components
Interferences and Limitations

Methylene blue will interfere with measurement of venous or arterial methemoglobin for approximately 24 hours after administration.

Measurements made less than a day after methylene blue therapy is given may give falsely low results for methemoglobin.

Ordering & Collection

Specimen Type
Venous blood
Collection

Venous blood collected into a balanced heparinized syringe such as the 2 mL Radiometer PicoTM or 3 mL Smiths Portex Pro-Vent syringes.

Handling Instructions

Needles must be removed from syringes and replaced with caps before sending to the lab. No air bubbles. Transport to Lab Immediately.

Note: The Laboratory MUST assay specimen within 30 minutes of blood collection.

Quantity
Requested: Full Syringe
Minimum: half of a full syinge

Processing

Receiving Instructions

This battery of tests will be done at patient bedside when a "CODE BLUE" is called.


Note: ML Tech will transport Mobile Blood Gas Cart to the floor.
The ML Tech is responsible for making out a request form, login of this panel & result entry.

Misc Sendout

Performance

Lab Department
Frequency
as requested
Available STAT?
Yes
Performing Location(s)
HMC Chemistry, Blood Gas (mobile)
206-520-4600

325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420

UW-NW Main Lab
206-668-1344

UW Medical Center – Northwest
1550 N 115th Street, A200
Seattle, WA 98133