Urine Culture and Sensitivity without Gram

tabbed view

General Information

Lab Name
Urine C/S
Lab Code
URNXC
Epic Ordering
Culture Urine, Bact
Description

Urine Bacterial Culture without Gram Stain

For culture with gram stain, see Urine Culture and Sensitivity with Gram [URNC]. For specimens collected by suprapubic aspiration, see Urine Culture and Sensitivity with Gram (Anaerobic) [URNANC] to include testing for anaerobes and/or fastidious organisms.

Synonyms
Components

Interpretation

Method

Culture

Reference Range
See individual components
Guidelines

Ordering & Collection

Specimen Type
Midstream Urine, Catheterized Urine (Please specify method of collection)
Collection

Collect midstream or catheterized urine in sterile cup. Immediately transfer urine to a gray top boric acid transport tube. Tubes have a 4 mL draw volume. A minimum fill line of 3 mL is indicated on the label. If specimen volume is <3mL, do not transfer urine to sample to a gray top tube.

Handling Instructions

Urine should be transferred to a gray top boric acid transport tube unless <3 mL.

Storage, Transport, and Stability

Gray top boric acid transport tube: Room Temperature: 48 h, Refrigerated: 48 h, Frozen: Unacceptable

Unpreserved (sterile cup): Room Temperature:2 h, Refrigerated:24 h, Frozen: Unacceptable

Note with UA: To expedite processing when urinalysis (UA) is also ordered, send separate specimen cup for UA.

Unacceptable: Leaking containers, unpreserved specimens >2 h at room temperature or > 24 h refrigerated, preserved specimens >48 h, frozen urine, preserved specimens with volume < minimum fill line (3 mL), urine collected from a Foley catheter bag, 24-hour or pooled specimens, Foley catheter tips.

Quantity
requested: 4 mL
minimum: 3 mL in gray top, 0.5 mL in sterile cup

Processing

Processing

Performance

LIS Dept Code
Microbiology (MC)
Performing Location(s)
UW-MT Microbiology
206-520-4600

Clinical Lab, Room # NW177,
University of Washington Medical Center,
1959 NE Pacific street, Seattle, WA 98195

Other Locations/Notes

UW-MT Microbiology performs testing for UW-MT, HMC and UW-NW

Frequency
Processed upon receipt
Available STAT?
No

Billing & Coding

CPT codes
87086
LOINC
630-4
Interfaced Order Code
UOW4258