Hepatitis D Quantitative PCR (Sendout)

General Information

Lab Name
Hepatitis D Quantitative PCR (Sendout)
Lab Code
RHEPDP
Epic Name
Hepatitis D Quantitative PCR (Sendout)
External Test Id
2013881
Description

Ordering Recommendation: Confirm and quantify the presence of hepatitis D virus.

Synonyms
2013881, HDV PCR, HDV Quantitative, Hepatitis Delta PCR
Components

Interpretation

Guidelines
Method

Quantitative Polymerase Chain Reaction

Reference Range
See individual components
Ref. Range Notes

Reference Interval: Not Detected

Interpretive Data:

The quantitative range of this assay is 2.1-6.8 log IU/mL (120 - 5,800,000 IU/mL).

A negative result (less than 2.1 log IU/mL or less than 120 IU/mL) does not rule out the presence of PCR inhibitors in the patient specimen or HDV RNA concentrations below the level of detection of the test. Inhibition may also lead to underestimation of viral quantitation.

Ordering & Collection

Specimen Type
Blood
Collection

3 mL blood in GOLD TOP tube (SST)

Note: This test requires a dedicated tube and cannot be shared.

Handling Instructions

Outside Laboratories: Centrifuge sample and freeze at -20°C. Do not aliquot or open the tube. This test requires a dedicated tube and cannot be shared.

Stability: Frozen: 4 months; Refrigerated: 1 week; Ambient: 24 hours.

Quantity
Requested: 1 mL serum in a spun, unopened gold SST
Minimum: 0.5 mL serum in a spun, unopened gold SST

Processing

Receiving Instructions

Centrifuge sample and freeze at -20°C. Do not aliquot or open the tube. This test requires a dedicated tube and cannot be shared.

Sendouts:

  • Order ARUP Test: 2013881.
  • Interfaced: Yes. [Interface Number: 602; Department: ARPZ]

Stability: Frozen (Preferred): 4 months; Refrigerated: 1 week; Ambient: 24 hours.

Note: Non-sterile samples may be run by ARUP with a disclaimer with approval by the ordering provider.

Misc Sendout

Performance

Lab Department
Sendouts ARUP Lab (FZ)(ARPZ)
Frequency
Performed: Mon & Thurs. Reported In: 2-5 days.
Available STAT?
No
Performing Location(s)
Sendout ARUP Laboratories, Inc.
800-522-2787

500 Chipeta Way
Salt Lake City, UT 84108

Billing & Coding

CPT Codes
87523
LOINC
80426-0
Interfaced Order Code
UOW4847