See tip sheet for more information (internal link).
UW-OncoPlex™ Single Gene (OPG) is intended to test a single gene selected from the UW-OncoPlex™ Panel. See below for the list of offered genes. Complete sequencing of all coding exons is available for most, but not all genes.
Please note that UW-OncoPlex Single Gene (OPG) is intended for solid tumors. For testing related to hematologic malignancies, please order Heme Single Gene by NGS [HCAPSG]. Consultation with a Director can be requested to determine the appropriate testing. Please contact the laboratory at 206-598-6429 for further questions.
This test is designed to detect somatic mutations in cancer and is not designed to detect germline (heritable) mutations.
This test can be used for extended RAS testing (KRAS exon 2, 3, 4 and NRAS exons 2, 3, 4 complete sequencing).
For information on the complete UW-OncoPlex™ Panel, see UW OncoPlex Cancer Gene Panel [OPX].
Code | Name |
---|---|
OPGGS | OncoPlex Single Gene Sequenced Gene |
OPGRE | OncoPlex Single Gene Result |
OPGIN | OncoPlex Single Gene Interpretation |
OPGCH | OncoPlex Single Gene Clinical Information |
OPGMT | OncoPlex Single Gene Method |
OPGDI | Oncoplex Single Gene Director |
Next-generation sequencing.
Genes listed above are sequenced on an Illumina instrument to detect single nucleotide variants, small insertions and deletions, gene amplifications, and selected translocations.
No mutations detected
Requirements for Specimen Selection
Specimen Types
Tissue samples
Send one of the following:
NOTE: In order to ensure that enough DNA is obtained, the minimum acceptable tissue area is 10 square millimeters when ten 10-micron slides are supplied (1 cubic millimeter of tissue).
Purified DNA
5 micrograms ANDa reference hematoxylin-and-eosin (H&E) stained slide and pathology report required.
Bone Marrow
1 to 2 mL Bone Marrow in LAVENDER TOP (EDTA) tube
Blood
6 mL blood in LAVENDER TOP (EDTA) tube.
Alternative specimens may be acceptable with approval (contact: 206-598-1149).
For ADD-ON after prior testing, contact Genetics lab.
Unacceptable samples
We cannot accept decalcified samples or tissue samples treated with fixatives other than formalin.
Quantity:
Requested:
Minimum:
Requisition Form and Ordering Instructions
1. Fill out a Genetics Requisition Form
Providers with access to the UW implementation of Epic (i.e., FHCC, HMC, SCCA, UWMC, UWNW) may order this test using the order "UW Genetics and Solid Tumor Test Request." See tip sheet for more information (internal link).
2. Check "UW-OncoPlex™ Cancer Single Gene"
3. Please indicate the gene(s) requested in clinical history space provided.
Genetics Preauthorization Form (preauthorization is only done for providers who are external to the UW system).
Attach a copy of the pathology report for the tumor sample being submitted. Include the flow cytometry report for leukemia (e.g., AML) samples.
Tissue: Hold slides or tissue blocks at room temperature. Outside Laboratory: Ship at room temperature. Stability: unstained slides or tissue blocks stable at room temperature for at least 2 years.
Purified DNA: Refrigerate DNA specimens. Frozen is acceptable.
Blood or Bone Marrow: Refrigerate whole blood and/or bone marrow Unacceptable Conditions: Frozen or clotted specimens
Stability (collection to initiation of testing): Ambient: 2 days; Refrigerated: 7 days
UW-MT |
Genetics
Attention: Genetics Lab Tel: 206-598–6429 M–F (7:30 AM–4:00 PM) Tel (EXOME only): 206-543-0459 |
Faculty |
---|
For additional test/billing information, see following pages:
For pricing information, contact Client Support Services 206-520-4600 or 800-713-5198.
Billing and Insurance Pre-Authorization
We offer insurance pre-authorization services (preauthorization is only done for providers who are external to the UW system).