ABO/Rh(D), Outside Client

General Information

Lab Name
ABO/Rh(D), Outside Client
Lab Code
OABRH
Description

ABO testing is performed to determine if patient has blood group of A, B, O or AB.

Rh testing is performed to determine if patient is Rh(D) Positive or Rh(D) Negative. Both ABO and Rh testing establishes the blood type of the patient.

ABO/Rh may be performed on automated analyzer or standard tube method.

"This test is orderable for approved clients only."

Synonyms
ABO/Rh, Blood type, RhD
Components
Code Name
%ABR ABO/Rh(D)

Interpretation

Reference Range
See individual components

Ordering & Collection

Specimen Type
Whole Blood
Collection

Preferred: 6 ml PINK TOP (EDTA) tube

Also acceptable: 6ml LAVENDER TOP (EDTA)

Specimen verification and collection:

  • Patient ID must be performed in the presence of the patient by the person collecting the specimen.
  • Label specimen in the presence of the patient.
  • Write collection date and time on specimen label. Printed collection date and time on label is acceptable as well.
Handling Instructions

Transport: Place specimen in separate biohazard bag and transport at room temperature

Quantity
Requested: 6 mL EDTA whole blood
Minimum: 3 mL EDTA whole blood

Processing

Receiving Instructions

For non UWMC clients: Specimen should be tested at UWMC Montlake Transfusion Services Lab as soon as possible after collection. If testing is delayed, the specimen should be stored at 2-8 C.

Batch and send specimen separate from other testing, indicate for “For Transfusion Services” on bag.

Complete UWMC TSL Immunohematology Consultation Form and send with specimen.

SPS: Receive batch from non UWMC clients and immediately send specimen to NN601, tube station: 361 for testing.

Misc Sendout

Performance

Lab Department
Blood Bank(BB)
Frequency
Daily
Available STAT?
No
Performing Location(s)
UW-MT Transfusion Service
206-520-4600

Clinical Lab, Room # NN601,
University of Washington Medical Center,
1959 NE Pacific street, Seattle, WA 98195

Billing & Coding

CPT Codes
86900, 86901
LOINC
882-1
Interfaced Order Code
UOW5424