Place a separate order to draw the paired blood sample.
See tip sheet for more information (internal link).
ColoSeq™ Tumor Single Gene is designed to detect somatic mutations in a single gene of ColoSeq™ Panel. Somatic mismatch repair (MMR) mutations have been reported in colon and endometrial cancers which have IHC loss of MMR protein(s) and normal (negative) germline MMR testing.
ColoSeq™ Tumor is an option for patients who have had abnormal MMR IHC and normal germline testing, such as ColoSeq™. ColoSeq™ Tumor Single Gene is a multiplexed assay for tumor samples that detect mutations in single gene selected by ordering provider. Next-generation sequencing is performed on an Illumina instrument to detect single nucleotide variants, insertions, deletions, gene amplifications, and selected translocations.
NOTE: If germline MMR testing was performed in a different laboratory, a peripheral blood sample should be submitted in addition to tumor tissue.
For information on the full ColoSeq™ Tumor Panel, see ColoSeq Tumor Panel [CSQTP]
For information on germline ColoSeq™ Lynch and Polyposis Panel (comprehensive colon cancer risk panel) see, ColoSeq - Lynch and Polyposis Panel [COSEQ]
ColoSeq™ Panel Genes
Gene |
RefSeq |
Disease Association or Cancer Risk |
Complete Sequencing |
Del/Dup |
Added |
AKT1 |
NM_005163.2 |
Cowden-like, Breast, thyroid cancers, macrocephaly |
Yes |
Yes |
October 2013 |
APC |
NM_000038.5 |
FAP, Turcot |
Yes |
Yes |
November 2011 |
AXIN2 |
NM_004655.3 |
Colon cancer, oligodontia |
Yes |
Yes |
February 2015 |
BMPR1A |
NM_004329.2 |
Juvenile Polyposis |
Yes |
Yes |
January 2013 |
CDH1 |
NM_004360.3 |
Hereditary diffuse gastric cancer |
Yes |
Yes |
June 2012 |
CHEK2 |
NM_007194.3 |
Li-Fraumeni-like |
Yes |
Yes |
February 2015 |
CTNNA1 |
NM_0011903.2 |
Hereditary diffuse gastric cancer |
Yes |
Yes |
October 2014 |
CTNNB1 |
NM_001904.3 |
Desmoid tumors |
Yes |
Yes |
February 2023 |
EPCAM |
NM_002354.2 |
Lynch |
Yes |
Yes |
November 2011 |
GALNT12 |
NM_024642.4 |
Colon cancer |
Yes |
Yes |
October 2013 |
MLH1 |
NM_000249.3 |
Lynch, Muir-Torre |
Yes |
Yes |
November 2011 |
MLH3 |
NM_001040108.1 |
Mismatch repair deficiency |
Yes |
Yes |
June 2020 |
MSH2, includes exon 1-7 inversion |
NM_000251.1 |
Lynch, Muir-Torre |
Yes |
Yes |
November 2011 |
MSH6 |
NM_000179.2 |
Lynch |
Yes |
Yes |
November 2011 |
MUTYH |
NM_001128425.1 |
MUTYH-associated polyposis |
Yes |
Yes |
November 2011 |
NTHL1 |
NM_002528.5 |
Colon polyposis (recessive) |
Yes |
Yes |
July 2016 |
PDGFRA |
NM_006206 |
GIST |
Yes |
Yes |
July 2016 |
PIK3CA |
NM_006218.2 |
Cowden-like, Breast, thyroid cancer, macrocephaly |
Yes |
Yes |
October 2013 |
PMS2 |
NM_000535.5 |
Lynch |
Yes |
Yes |
November 2011 |
POLD1 |
NM_002691.3 |
Colon cancer |
Yes |
Yes |
October 2013 |
POLE |
NM_006231.2 |
Colon cancer |
Yes |
Yes |
October 2013 |
PTEN |
NM_000314.4 |
Cowden |
Yes |
Yes |
June 2012 |
RPS20 |
NM_001023.3 |
Colon cancer |
Yes |
Yes |
February 2015 |
SMAD4 |
NM_005359.5 |
Juvenile Polyposis |
Yes |
Yes |
January 2013 |
TP53 |
NM_000546.5 |
Li-Fraumeni |
Yes |
Yes |
June 2012 |
Single Gene Testing available for any gene on ColoSeq™
For information on single gene testing see BROCA/ColoSeq - Single Gene Analysis [SGN]
Known Mutation Testing
Known mutation testing is available for mutations identified at UW Laboratory Medicine. For information on single site testing of a known mutation in one of the genes listed above see BROCA/ColoSeq™ - Known Mutation Testing [KMU]
For information about how University of Washington Department of Laboratory Medicine reports variants, see Variant Classification and Clinical Reporting of Results.
For previous versions of ColoSeq™ - Lynch and Polyposis Panel, see Previous Versions, COSEQ.
Code | Name |
---|---|
CTSGS | ColoSeq Tumor Gene Analyzed |
CTSRE | ColoSeq Tumor Result |
CTSIN | ColoSeq Tumor Interpretation |
CTSCH | ColoSeq Tumor Clinical History |
CTSMT | ColoSeq Tumor Method |
CTSDI | ColoSeq Tumor Director |
Next-generation sequencing.
This assay sequences all exons, non repeating intronic sequences and select promoter regions of AKT1, APC, AXIN2, BMPR1A, CDH1, CHEK2, CTNNA1, CTNNB1, EPCAM, GALNT12, MLH1, MLH3, MSH2, MSH6, MUTYH, NTHL1, PDGFRA, PIK3CA, PMS2, POLE, POLD1, PTEN, RPS20, SMAD4, and TP53. Sequences are aligned to the human genome reference (hg19). Test performed by targeted capture for listed genes followed by next-generation sequencing with Illumina technology. This test was developed and its performance characteristics determined by the University of Washington Department of Laboratory Medicine. It has not been cleared or approved by the US Food and Drug Administration. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.
No mutations detected
Tumor specimen will be requested directly, by UW Laboratory Medicine, from the originating pathology department. In order to facilitate this, a pathology report should be submitted with the test requisition, blood control and other clinical and billing paperwork. NOTE: This test requires BOTH tumor tissue and peripheral blood. Only tumor tissue is required if ColoSeq™ testing on peripheral blood has been done previously at UW Lab Medicine.
Tumor Tissue:
Tumor specimen will be requested directly, by UW Laboratory Medicine, from the originating pathology department. In order to facilitate this, a pathology report should be submitted with the test requisition, blood control and other clinical and billing paperwork.
If the tumor specimen is being submitted by the ordering provider, tissue samples (FFPE) either (a) slides, OR (b) tissue block are required.
(a) Instructions for slide specimens: 1 slide at 4-micron thickness stained with hematoxylin-and-eosin AND 20 unstained, non-baked slides at 10-micron thickness (a minimum of 10 unstained slides is acceptable). Unstained slides can be on charged or uncharged slides. Note: Sections should contain as much tumor tissue as possible.
(b) Instructions for tissue block specimen: Provide complete tissue block containing tumor tissue. If there is more than one tissue block, please provide the block that has the greatest amount of tumor tissue. Tissue block will be returned at completion of testing. Ship at room temperature.
NOTE: If germline MMR testing was performed in a different laboratory, a peripheral blood sample should be submitted in addition to tumor tissue.
Germline control sample:
BLOOD:
SALIVA:
Contact laboratory for validated collection kit.
SKIN BIOPSY:
CULTURED CELLS:
Requisition Form and Ordering Instructions
1. Fill out a Genetics Requisition Form
Providers with access to the UW implementation of Epic (i.e., FHCC, HMC, SCCA, UWMC, UWNW) may order this test using the order "UW Genetics and Solid Tumor Test Request." See tip sheet for more information (internal link).
2. Check "ColoSeq™ - Tumor Single Gene".
3. Specify gene in space provided.
4. Unless prior germline testing was performed at University of Washington, also select: "Normal Control (blood)".
5. Select the appropriate “Specimen Submitted".
6. Submit test requisition with peripheral blood sample and a copy of the tumor pathology report.
NOTE: Tumor specimen will be requested directly, by UW Laboratory Medicine, from the originating pathology department, and therefore, in most cases, it is not necessary to submit tumor block or slides.
Attach a copy of the pathology report for the tumor sample being submitted.
Ship specimen at room temperature for overnight delivery.
Blood specimens can be held for up to 7 days before shipping if refrigerated.
Ship specimens to:
UW MEDICAL CENTER
LABORATORY MEDICINE - GENETICS LAB
1959 NE PACIFIC ST, ROOM NW220
SEATTLE, WA 98195-7110
Blood: Refrigerate whole blood
Unacceptable Conditions: Frozen or clotted specimens
Stability (collection to initiation of testing): Ambient: 5 days; Refrigerated: 7 days; Frozen: Unacceptable
Purified DNA: Refrigerate DNA specimens. Frozen is acceptable.
UW-MT |
Genetics
Attention: Genetics Lab Tel: 206-598–6429 M–F (7:30 AM–4:00 PM) Tel (EXOME only): 206-543-0459 |
Faculty |
---|
For additional test/billing information, see ColoSeq™ Tumor Single Gene CPT codes.
For pricing information, contact Client Support Services 206-520-4600 or 800-713-5198.
Billing and Insurance Pre-Authorization
We offer insurance pre-authorization services (preauthorization is only done for providers who are external to the UW system).
Email: gpab@uw.edu or call 1-855-320-4869 for more information.
A letter of medical necessity is highly recommended for ColoSeq™ Tumor testing, and a template is available by emailing genelab@uw.edu.