Trypanosoma cruzi Antibody Panel (Sendout)

This test replaces Trypanosoma cruzi Total Antibody (Sendout) [RCHAGS]

General Information

Lab Name
Trypanosoma cruzi Antibody Panel (Sendout)
Lab Code
RCRUZI
Epic Name
Trypanosoma cruzi Antibody Panel (Sendout)
External Test Id
CRUZI
Description

Useful For: Diagnosis of chronic Trypanosoma cruzi infection (Chagas disease) using two different methods.

    Ordering Guidance: This panel includes two independent T. cruzi antibody assays performed using different methods, as recommended by the CDC for serologic diagnosis of Chagas disease¹. If results are discordant, additional testing may be required for resolution. Contact the Laboratory Medicine Resident or Microbiology fellow on-call for guidance on subsequent testing.

    References
    1. Centers for Disease Control and Prevention (CDC): Laboratory Diagnosis of American Trypanosomiasis
    2. Mayo Clinic Labs Clinical & Interpretive Information: Trypanosoma cruzi (Chagas) Antibody Panel, Serum
    Synonyms
    American trypanosomiasis, Chagas, Chagas disease, CRUZI, Kissing bug, RCHAGS, Reduviid, T. cruzi, Triatoma, Trypanosoma, Trypanosomiasis
    Components

    Interpretation

    Guidelines
    Method

    Enzyme-Linked Immunosorbent Assay (ELISA), Lateral Flow Assay (LFA)

    Reference Range
    See individual components
    Ref. Range Notes

    Reference Values:

    Trypanosoma cruzi Total Antibody, EIA: Negative
    Trypanosoma cruzi IgG, LFA: Negative

    Additional interpretive information is available on the Mayo website.²

    Interferences and Limitations

    Cautions:

    False-positive results may occur in patients infected with Leishmania species or other Trypanosoma species, including Trypanosoma rangeli. Additionally, false-positive results with the T cruzi lateral flow assay have been detected in patients with hepatitis C, toxoplasmosis, or syphilis.

    A diagnosis of chronic Chagas disease requires both clinical evaluation (including exposure history) and laboratory results. Chagas disease should not be diagnosed based on a single serologic result alone.

    A single negative result does not exclude the diagnosis of Chagas disease as antibodies to the pathogen may not yet be detectable. Sensitivity of the assay may be decreased in significantly immunosuppressed patients.

    References
    1. Centers for Disease Control and Prevention (CDC): Laboratory Diagnosis of American Trypanosomiasis
    2. Mayo Clinic Labs Clinical & Interpretive Information: Trypanosoma cruzi (Chagas) Antibody Panel, Serum

    Ordering & Collection

    Specimen Type
    Blood
    Collection

    3 mL blood in RED or GOLD SST tube

    Handling Instructions

    Outside Laboratories: Centrifuge sample and aliquot serum to a separate plastic vial. Freeze serum at -20°C while awaiting shipment. Transport on dry ice.

    Stability: Frozen (Required): 14 days; Refrigerated: Unacceptable; Ambient: Unacceptable.

    Reject Due To: Gross hemolysis, gross lipemia.

    Quantity
    Requested: 0.7 mL serum
    Minimum: 0.5 mL serum

    Processing

    Receiving Instructions

    Centrifuge sample and aliquot serum to a separate plastic vial. Freeze serum at -20°C.

    Sendouts:

    • Order Mayo Test: CRUZI
    • Interfaced: Yes [Interface: 601; Worksheet: MAFZ]

    Stability: Frozen (Required): 14 days; Refrigerated: Unacceptable; Ambient: Unacceptable.

    Reject Due To: Gross hemolysis, gross lipemia.

    Misc Sendout

    Performance

    Lab Department
    Sendouts Mayo Lab (FZ)(MAFZ)
    Frequency
    Performed: Monday. Reported: 1-8 days from sample receipt at Mayo Clinic Labs.
    Available STAT?
    No
    Performing Location(s)
    Sendout Mayo Clinic Laboratories (Superior Drive)
    800-533-1710

    3050 Superior Drive NW
    Rochester, MN 55901

    Billing & Coding

    CPT Codes
    86753x2
    Interfaced Order Code
    UOW6010
    Interfaced Result Code
    UOW6013