Code Panel, Arterial blood
General Information
- Lab Name
- Code Panel, ART
- Lab Code
- ACODE2
- Epic Name
- Code Panel, Arterial, w/ Lact, iCa, Na, K, Glu, HbCO, Met HGB
- Description
Instructions for Outside Labs: This battery of tests will be done at patient bedside when a "CODE BLUE" is called.
- Components
-
Code Name ABGC Blood Gas Battery, Codes, ART PH pH, ART PCO2 pCO2, ART PO2 pO2, ART HCO3 Bicarbonate, WBLD BEXS Base Excess, Blood, ART BDEFC Base Deficit, Blood, ART ACX Cooximetry Panel, ART ACXSD Spec Description, Coox ART THB Total Hemoglobin, ART O2FR O2 Saturation (Frac.), ART ABCO Carboxyhemoglobin, ART AMHB Methemoglobin, ART OCON O2 Content, ART O2FU O2 Saturation (Func.), ART WALAC L_Lactate, Arterial Whole Blood WGLU Glucose, WBLD WHCTG Immediate Care HGB and HCT WHB Immediate Care Hemoglobin WIC Calcium (Ionized), WBLD WINCA Calcium (Ionized), WBLD WK Potassium, WBLD WNA Sodium, WBLD
Interpretation
- Method
THB: Photodiode array; O2FR: Photodiode array; AMHB: Photodiode array; WALAC: Lactate Oxidase; WGLU: Glucose oxidase
- Reference Range
- See individual components
- Interferences and Limitations
Methylene blue will interfere with measurement of venous or arterial methemoglobin for approximately 24 hours after administration. Measurements made less than a day after methylene blue therapy is given may give falsely low results for methemoglobin.
Ordering & Collection
- Specimen Type
- Arterial Blood
- Collection
-
Arterial blood collected into a balanced heparinized syringe such as the 2 mL Radiometer PicoTM or 3 mL Smiths Portex Pro-Vent syringes.
- Handling Instructions
Needles must be removed from syringes and replaced with caps before sending to the lab. No air bubbles. Transport to Lab Immediately.
- Quantity
-
Requested: Full Syringe
Minimum: half of a full syinge
Processing
- Receiving Instructions
This battery of tests will be done at patient bedside when a "CODE BLUE" is called.
Note: ML Tech will transport Mobile Blood Gas Cart to the floor. The ML Tech is responsible for making out a request form, login of this panel & result entry.
- Misc Sendout
Performance
- Lab Department
- Frequency
- as requested
- Available STAT?
- Yes
- Performing Location(s)
-
HMC Chemistry, Blood Gas (mobile)
206-520-4600325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420
Billing & Coding
- CPT Codes
- 82330, 82375, 82805, 82947, 83050, 83605, 84132, 84295, 85018
- LOINC
- 18767-4