NMDA Receptor IgG Antibody with Reflex, Serum (Sendout)
General Information
- Lab Name
- NMDA Receptor IgG Antibody w/Reflex, Serum (Sendout)
- Lab Code
- RNMDAG
- Epic Ordering
- NMDA Receptor Ab, IgG W/Reflex, Serum (Sendout)
- External Test Id
- 2004221
- Description
Ordering Recommendation: Confirm diagnosis of anti-NMDAR encephalitis. May be used in monitoring treatment response in individuals who are antibody positive.
Test Algorithm: If the NMDA Antibody IgG is positive, then an NMDA Antibody IgG Titer is performed at additional charge.
Ordering Note: This test is for serum samples only. For NMDA-R Antibody testing on CSF, refer to NMDA Receptor IgG Antibody with Reflex, CSF (Sendout) [RCNMDA].
- Synonyms
- 2004221, Anti NMDA, Anti-GluN1, Anti-NMDA, Anti-NR1, Glutamate Receptor Antibodies, Limbic Encephalitis, N-methyl-D-aspartate receptor, NMDA IgG, Paraneoplastic
- Components
-
Code Name RNMDA NMDA Receptor IgG Antibody w/Reflex, Serum (Sendout) RNMDAR NMDA Receptor IgG Antibody, Serum UW424 Study: NMDA Receptor Abs, SRM
Interpretation
- Method
Semi-Quantitative Cell-Based Indirect Fluorescent Antibody
- Reference Range
- See individual components
- Ref. Range Notes
Reference Range: < 1:10 Interpretive Data: NMDA receptor antibody is found in a subset of patients with autoimmune limbic encephalitis and may occur with or without associated tumor. Decreasing antibody levels may be associated with therapeutic response. In addition, positive results have been reported in patients with nonautoimmune phenotypes. A negative test result does not rule out a diagnosis of autoimmune limbic encephalitis. Results should be interpreted in correlation with the patients clinical history and other laboratory findings. Serum testing should be paired with CSF testing for improved diagnostic sensitivity.
This indirect fluorescent antibody assay utilizes full-length GluN1 transfected cell lines for the detection and semiquantification of NMDA receptor IgG antibody.
- Guidelines
Ordering & Collection
- Specimen Type
- Blood
- Collection
-
6 mL blood in RED TOP tube or GOLD SST
- Handling Instructions
Outside Laboratories: Centrifuge sample and transfer serum to a separate vial within 2 hours of collection. Refrigerate serum.
Stability: Refrigerated (preferred): 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles); Ambient: 48 hours.
Unacceptable Conditions: CSF or plasma. Contaminated, hemolyzed, or severely lipemic specimens.
- Quantity
-
requested: 1 mL serum + 1 mL serum for UW424
minimum: 0.2 mL serum
Processing
- Processing
Centrifuge sample and transfer 1 mL serum each into two separate plastic vials within 2 hours of collection. If sample volume is low, prioritize the sendout test (RNMDA).
- UW424: Freeze serum at -20°C in Immunology rack.
- RNMDA: Store serum in Sendouts Refrigerated ARUP rack.
Sendouts:
- Order ARUP Test: 2004221
- Interfaced: Yes [Interface: 602; Department: ARPR]
Stability: Refrigerated (preferred): 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles); Ambient: 48 hours.
Unacceptable Conditions: CSF or plasma. Contaminated, hemolyzed, or severely lipemic specimens.
Performance
- LIS Dept Code
- Performing Location(s)
-
Sendout ARUP Laboratories, Inc.
800-522-2787500 Chipeta Way
Salt Lake City, UT 84108 - Frequency
- Performed: Sunday through Saturday. Reported: 1-3 days from sample receipt.
- Available STAT?
- No
Billing & Coding
- CPT codes
- 86255
- LOINC
- 80221-5