Blood Gas Panel 9, ART

Interpretation

Method

THB: Photodiode array; O2FR: Photodiode array; AMHB: Photodiode array; WGLU:Glucose Oxidase; WALAC: Lactate Oxidase

Reference Range
See individual components
Interferences and Limitations

Methylene blue will interfere with measurement of venous or arterial methemoglobin for approximately 24 hours after administration. Measurements made less than a day after methylene blue therapy is given may give falsely low results for methemoglobin.

Ordering & Collection

Specimen Type
Arterial blood
Collection

Arterial blood collected into a balanced heparinized syringe such as the 2 mL Radiometer PicoTM or 3 mL Smiths Portex Pro-Vent syringes.

Handling Instructions

Needles must be removed from syringes and replaced with caps before sending to the lab. No air bubbles. Transport to Lab Immediately.
Note: The Laboratory MUST assay specimen within 30 minutes of blood collection.

Quantity
Requested: Full Syringe
Minimum: half of a full syinge

Processing

Receiving Instructions
Misc Sendout

Performance

Lab Department
Chemistry, Whole Blood(CHW)
Frequency
Available STAT?
Performing Location(s)
HMC Chemistry, Blood Gas (OR)
206-520-4600

325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420

Billing & Coding

CPT Codes
82330, 82375, 82805, 82947, 83050, 83605, 84132, 84295, 85018
LOINC
18767-4