Apolipoprotein E Genotyping, Cardiovascular Risk (Sendout)
General Information
- Lab Name
- Lab Code
- 377
- External Test Id
- 2013337
- Description
Ordering Recommendation: Provide supporting evidence for a diagnosis of type III hyperlipoproteinemia for evaluation of premature coronary heart disease.
Note: This test is not recommended for nonsymptomatic patients under 18 years of age.
Ordering Guidance: For ApoE testing to inform lecanemab therapy decisions, refer to separate test #1096, Apolipoprotein E (APOE) Genotyping, Lecanemab Therapy Risk (Sendout).
- Synonyms
- 2013337, Apo E Genotype, APOE, Apolipoprotein E Mutation Analysis
Interpretation
- Method
Polymerase Chain Reaction/Fluorescence Monitoring
- Ref. Range Notes
Reference Interval: Homozygous APOE e3 (e3/e3): This genotype is the most common (normal) genotype.
- Interferences and Limitations
Limitations: Only the e2, e3 and e4 variants will be detected. Rare isoforms of APOE will not be detected. If rare alleles are suspected, phenotyping by isoelectric focusing may be indicated. Diagnostic errors can occur due to rare sequence variations.
Ordering & Collection
- Specimen Type
- Blood
- Collection
-
3 mL blood in LAVENDER TOP (EDTA) tube
Also Accepted: Yellow (ACD Solution A or B) or Pink (K2EDTA)
- Handling Instructions
Outside Laboratories: Refrigerate whole blood in original collection container.
Stability: Refrigerated (preferred): 1 week; Ambient: 72 hours; Frozen: 1 month.
Unacceptable Conditions: Plasma or serum. Heparinized specimens. Frozen specimens in glass collection tubes.
- Quantity
-
requested: 3 mL whole blood
minimum: 1 mL whole blood
Processing
- Processing
Refrigerate whole blood in original collection container.
Login: GSEND1-;REFRIG
- GSNDT1: ARUP
- GSTYP1: WB
- GTSRQ1: ;Apolipoprotein E Genotype (ARUP Test 2013337)
Sendouts: order ARUP Test: 2013337.
Stability: Refrigerated (preferred): 1 week; Ambient: 72 hours; Frozen: 1 month.
Unacceptable Conditions: Plasma or serum. Heparinized specimens. Frozen specimens in glass collection tubes.
Performance
- LIS Dept Code
- Performing Location(s)
-
Sendout ARUP Laboratories, Inc.
800-522-2787500 Chipeta Way
Salt Lake City, UT 84108 - Frequency
- Performed: Mon, Thurs. Reported: 2-7 days.
- Available STAT?
- No
Billing & Coding
- CPT codes
- Billing Comments
CPT: 81401
- LOINC